5.4Bus organisation
The idea
Internal buses carry data between registers. More buses allow more transfers in the same cycle, so fewer cycles per instruction.
Think of it like this: A one-lane road versus a three-lane highway.
Why it exists
It is how designers trade hardware cost for speed.
How it works
- Single bus: only one value can travel per cycle, so temporary registers (Y, Z) are needed.
- Two bus: two sources can move at once.
- Three bus: two sources and one destination simultaneously: ADD in one cycle.
Worked example: ADD R1, R2, R3
Single bus: 3 cycles. Three bus: 1 cycle.
Now play with it
- →Compare the two tabs and count steps.
- Cycle 1: R2out, Yin. R2 → bus → Y
- Cycle 2: R3out, ADD, Zin. R3 on bus, ALU adds Y + bus, result in Z
- Cycle 3: Zout, R1in. Z → bus → R1
ADD R1,R2,R3 takes 3 cycles because only one value can be on the bus per cycle.
Check yourself
On a 3-bus datapath, ADD R1,R2,R3 (register operands) takes how many clock cycles for the execute step?
Exam notes (the dense version)
More internal buses ⇒ more parallel transfers per cycle ⇒ fewer cycles per instruction. 1-bus: ALU needs temp registers (Y, Z). 3-bus: two sources + one destination at once.
Previous year questions: ALU, Datapath & Control Unit (3)
PYQs are grouped by topic, so this is the full set for ALU, Datapath & Control Unit; try the ones that match this subtopic. Open all 3 on the topic page.