← 🧠 ALU, Datapath & Control Unit
Subtopic 5 of 9

5.5Hardwired control

The idea

A hardwired control unit generates control signals with fixed logic gates driven by the opcode and a timing counter.

Think of it like this: A music box: the mechanism itself is the tune, very fast but cannot be changed.

Why it exists

No lookup is needed, so it is the fastest control design.

How it works

  1. The opcode is decoded.
  2. A step counter says which cycle (T1, T2...) we are in.
  3. AND/OR gates combine opcode, step and flags.
  4. The outputs are the control signals.

Worked example: ADD, step T3

Signals R2out and Yin fire in this step; the next step fires R3out, ADD, Zin.

Now play with it

  • →Step through and follow the signal from IR to the control outputs.
IR (opcode)ADD
Decoder-
Step counter TT1
AND-OR logic-
Control signals-
  • Opcode in IR drives the decoder
  • Step counter (from clock) selects the current timing step
  • Gates combine the decoded line, the T-step and flags
  • Output = control signals (e.g. R2out, Yin), no memory lookup needed
  • Next clock: T4 and a new set of signals

Hardwired: the logic itself is the control unit (fast, hard to change).

Check yourself

Which type of control unit is generally faster?

Remember: Hardwired = fast, rigid, used in RISC.
Exam notes (the dense version)

Control signals from logic gates / state counter. Fast, hard to modify, used in RISC.

Previous year questions: ALU, Datapath & Control Unit (3)